Front | Back |
Increased TR
|
Increased Longitudinal Relaxation
Increase S/N
Increase of max. allowable slices
increased scan time
decrease T1 weghted contrast
|
Increased TE
|
Increase transverse relaxation
increases T2 weighted contrast
decrease S/N
decreases number of allowable slices
Increased gradient echo susceptiblility
|
Increased Inversion Time
|
Decrease T1 weight contrast
Very short: null fat (STIR)
Long: Null CSF (FLAIR)
|
Larger flip angle
|
Better S/N
|
Increased Slice Thickness
|
Increased S/N
more anatomical coverage
increased partial voume artifacts
Decreased spatial resolution
|
Increasing Gap
|
Decreased cross talk
Increased anatomical coverage
Increased risk of missing important anatomy/pathology
|
Increased Matrix: Phase Steps (Y)
|
Decreased S/N
Increased spatial resolution
increased scan time
|
Increased Matrix: Frequency Steps
|
Decreased S/N
Increased spatial resolution
no affect on scan time
|
Increased Nex
|
Increased S/N
increase scan time
decrease motion artifacts
|
Increased Receiver Bandwidth
|
Decreased S/N
decreased chemical shift artifact
no affect on scan time
|