Front | Back |
Increasing the receiver bandwidth with increase or decrease S/N?
|
Decrease
|
Increasing the receiver bandwidth with increase or decrease chemical shift artifacts?
|
Decrease
|
Increasing the receiver bandwidth does what to scan time?
|
Does not affect it.
|
Increasing the signal averages will increase or decrease S/N?
|
Increase
|
Increasing the signal averages with increase or decrease scan time?
|
Increase
|
Increasing the signal averages will increase or decrease motion artifacts?
|
Decrease
|
Increasing the echo train length will increase or decrease S/N?
|
Decrease
|
Increasing the echo train length will increase or decrease scan time?
|
Decrease
|
Increasing the parallel imaging factor will increase or decrease the scan time?
|
Decrease
|
Increasing the parallel imaging factor will increase or decrease the S/N?
|
Decrease the S/N
|
Increasing the parallel imaging factor will do what to a full field of view?
|
Maintain
|
Increasing the parallel imaging factor will do what to spatial resolution?
|
HAVE NO AFFECT!
|
Increasing the rectangular field of view will do what to the amount of anatomy displayed?
|
Increase the amount of anatomy displayed
|
Increasing the rectangular field of view will do what to S/N?
|
Increase the S/N
|
Increasing the rectangular field of view will do what to the scan time?
|
Increase
|