Front | Back |
The maximum temperature for type b pipe is?
|
550 degrees f.
|
What type of flue does a wall furnace use?
|
Type BW
|
What type of pipe do you use if the temperature exceeds 550 degrees
|
Type L
|
If a condensing gas furnace flue gas is less than 140 degrees what type of vent piping is used
|
PVC
|
What capacity rating would be used to determine the efficiency of the gas furnace?
|
Output capacity
|
What is the definition of temperature rise
|
The difference between return and supply air
|
List four types of forced air gas furnaces
|
Up flow, down flow, horizontal, and multi positional
|
What is the function of a gas furnace
|
To produce useful heat necessary to raise the comfort level of a home or building.
|
Heat exchangers are designed to produce what?
|
A rapid transfer of heat from the combustion products to the supply air.
|
Air which enters the burners and mixes with the gas before ignition, is known as what
|
Primary air
|
What percentage of the combustion air is referred to as excess air?
|
The additional 5 cubic feet (50%)
|
Products of combustion enter the draft hood and mix with air surrounding the furnaces. this additional air is known as
|
Dilution air
|
What are the two types of blower motors used with forced air furnaces?
|
Belt drive and direct drive blower
|
How many inches of water column (W.C.) will make one PSI of pressure?
|
Equal to 27 inches of W.C.
|
The instrument most commonly used to measure gas pressure is what?
|
U-tube monometer
|