Front | Back |
During an inspection, an inspector
needs to remove the service panel cover to determine ______
a. Type
of branch circuit wiring
b. Amount
of trash in the panel
c. The
accuracy of breaker labeling
d. The
insurability of the properly
|
A
|
While inspecting a tar and gravel
roof, what would indicate that the roof is failing?
a. Delamination
b. Loose
gravel
c. Ponding
of water on a roof
d. Gravel
has been washed to the down spouts.
|
A
|
KD-19 wood is dried to a moisture
content of _____% or more
a. 10
b. 16
c. 19
d. 21
|
C
|
Green lumber has a moisture
content of _____% or more.
a. 10
b. 15
c. 20
d. 25
|
C
|
The highest grade lumber is
called ______
a. MC-15
b. K-Dry
c. S-Dry
d. GRN
|
A
|
During an inspection, which item
must be tested?
a. A
stand-alone portable dishwasher
b. Self-cleaning
feature of an oven
c. Bathroom
exhaust fan
d. Self-cleaning
feature of a broiler
|
C
|
Per the rules of TREC, which
plumbing system item needs to be inspected during an inspection?
a. Any
components which are not visible
b. Any
components which are not accessible
c. Termination
of a vent through the roof line
d. Drain
pumps
|
C
|
The color of the ground wire in a
3 wire electrical system is _____
a. Green
b. Black
c. White
d. Gray
|
A
|
Polarity is achieved by which 2
wires of a 3 wire electrical system?
a. Neutral
and ground
b. Neutral
and hot
c. Ground
and hot
d. Bare
and ground
|
B
|
When inspecting a dishwasher,
which item does not need to be done?
a. Look
for signs of rust
b. Check
to insure the dishwasher is securely mounted
c. Check
the soap dish
d. Determine
water temperature
|
D
|
A junction box must be how high
above a deck?
a. 4
inches
b. 6
inches
c. 8
inches
d. 12
inches
|
A
|
Downwarping occurs when:
a. Moist
clay soil expands along the foundation perimeter.
b. Moisture
along the foundation perimeter is removed.
c. Expansive
clay soil dries and then shrinks along the foundation perimeter causing the
foundation to settle.
d. Expansive
clay soil dries then shrinks along the foundation perimeter causing the
foundation to rise.
|
C
|
While inspecting a pre-1955
residential one story home, an inspector notes a bare incandescent light bulb
mounted on the ceiling in the middle of a habitable room. What comment should be written in the
inspection report?
a. It
is a safety issue and in need of repair
b. None
required as this was done before 1955
c. Note
a safety violation by should be replaced at homeowner’s convenience
d. It
is not a safety violation, but repair is recommended.
|
D
|
An inspector notes that the
electrical wiring system is a 2 wire system and that all of the outlets in the
house are 2 prong. What comment should
the inspector make?
a. Electrical
system is satisfactory but not as safe as with a 3 wire system
b. Electrical
system is unsafe and should be replaced with a 3 wire system
c. Electrical
system is satisfactory
d. Electrical
system is a fire hazard
|
A
|
An inspector notices that the
bottom of a truss is separating from the top of the center wall which supports
the truss. What is the likely cause?
a. Cupping
b. Doming
c. Horizontal
twisting
d. Horizontal
shearing
|
A
|